Preparación de canales curvos y calcificados
Contenido principal del artículo
Resumen
Descargas
Detalles del artículo
No se permite un uso comercial de la obra original ni de las posibles obras derivadas, la distribución de las cuales se debe hacer con una licencia igual a la que regula la obra original.
Citas
Schilder H. Cleaning and shaping the root canal. Dent Clin North Am. 1974 Apr;18(2):269-96.
Abou-Rass M, Frank AL, Glick DH. The anticurvature filing method to prepare the curved root canal. J Am Dent Assoc. 1980 Nov;101(5):792-4.
Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol. 1971 Aug;32(2):271-5.
Bishop K, Dummer PM. A comparison of stainless steel Flexofiles and nickel-titanium NiTiFlex files during the shaping of simulated canals. Int Endod J. 1997 Jan;30(1):25-34.
Buchanan LS. Management of the curved root canal. J Calif Dent Assoc. 1989 Apr;17(4):18-25, 7.
Nguy D, Sedgley C. The influence of canal curvature on the mechanical efficacy of root canal irrigation in vitro using real-time imaging of bioluminescent bacteria. J Endod. 2006 Nov;32(11):1077-80.
Goerig AC, Michelich RJ, Schultz HH. Instrumentation of root canals in molar using the step-down technique. J Endod. 1982 Dec;8(12):550-4.
Senia SE, Johnson B, McSpaddwn J. The crown-down technique: a paradigm shift. Interview by Donald E. Arens. Dent Today. 1996 Aug;15(8):38-47.
Fishelberg G, Pawluk JW. Nickel-titanium rotary-file canal preparation and intracanal file separation. Compend Contin Educ Dent. 2004 Jan;25(1):17-8, 20-2, 4; quiz 5, 47.
Sayin TC, Serper A, Cehreli ZC, Otlu HG. The effect of EDTA, EGTA, EDTAC, and tetracycline-HCl with and without subsequent NaOCl treatment on the microhardness of root canal dentin. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007 Sep;104(3):418-24.
Lazzaretti DN, Camargo BA, Della Bona A, Fornari VJ, Vanni JR, Baratto Filho F. Influence of different methods of cervical flaring on establishment of working length. J Appl Oral Sci. 2006 Oct;14(5):351-4.
Plotino G, Grande NM, Cordaro M, Testarelli L, Gambarini G. Measurement of the trajectory of different NiTi rotary instruments in an artificial canal specifically designed for cyclic fatigue tests. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009 Sep;108(3):e152-6.
Van der Sluis LW, Wu MK, Wesselink PR. The efficacy of ultrasonic irrigation to remove artificially placed dentine debris from human root canals prepared using instruments of varying taper. Int Endod J. 2005 Oct;38(10):764-8.
Weiger R, Bruckner M, ElAyouti A, Lost C. Preparation of curved root canals with rotary FlexMaster instruments compared to Lightspeed instruments and NiTi hand files. Int Endod J. 2003 Jul;36(7):483-90.
Mohammadi Z. Sodium hypochlorite in endodontics: an update review. Int Dent J. 2008 Dec;58(6):329-41.
Siqueira JF, Jr., Rocas IN, Santos SR, Lima KC, Magalhaes FA, de Uzeda M. Efficacy of instrumentation techniques and irrigation regimens in reducing the bacterial population within root canals. J Endod. 2002 Mar;28(3):181-4.
Pecora JD, Capelli A, Guerisoli DM, Spano JC, Estrela C. Influence of cervical preflaring on apical file size determination. Int Endod J. 2005 Jul;38(7):430-5.
Hulsmann M, Heckendorff M, Lennon A. Chelating agents in root canal treatment: mode of action and indications for their use. Int Endod J. 2003 Dec;36(12):810-30.
Dotto SR, Travassos RM, de Oliveira EP, Machado ME, Martins JL. Evaluation of ethylenediaminetetraacetic acid (EDTA) solution and gel for smear layer removal. Aust Endod J. 2007 Aug;33(2):62-5.
Zhuang ZX, Ren F, He ZF. [Clinical analysis of fine root canal preparation with ProTaper rotary instruments]. Nan Fang Yi Ke Da Xue Xue Bao. 2007 Dec;27(12):1875-7.